2023 Valid 5V0-21.21 Real Exam Questions, practice VMware Certified Master Specialist [Q14-Q32]

Share

2023 Valid 5V0-21.21 Real Exam Questions, practice VMware Certified Master Specialist

Latest Success Metrics For Actual 5V0-21.21 Exam (Updated 52 Questions)


VMware 5V0-21.21 (VMware HCI Master Specialist) Exam is a certification exam that validates a professional's knowledge and skills in designing, implementing, and managing VMware vSAN-based hyper-converged infrastructure (HCI) solutions. 5V0-21.21 exam is designed for IT professionals who work with vSAN and are responsible for deploying, managing, and troubleshooting VMware HCI solutions. The VMware HCI Master Specialist certification is intended to demonstrate a candidate's mastery of the skills required to design, implement, and manage complex vSAN-based HCI solutions.


VMware HCI Master Specialist certification is a valuable credential for IT professionals who work with VMware technologies, as it demonstrates their advanced skills and expertise in designing and managing VMware HCI solutions. VMware HCI Master Specialist certification is recognized by industry leaders and can help candidates to advance their careers in areas such as system administration, network engineering, and cloud computing. Passing the VMware 5V0-21.21 exam requires dedication and hard work, but the rewards of earning this certification can be significant.

 

NEW QUESTION # 14
A customer is planning to migrate their physical Microsoft SQL Server clustered workloads to vSAN enabled vSphere clusters.
The following requirements must be met:
* Each MSSQL cluster is made up of 3 nodes
* Highest possible availability against node failures
* Some of the vSAN clusters will only consume storage
What should the architect recommend?

  • A. vSAN iSCSI Target Service
  • B. vSAN File Services
  • C. Stretched vSAN Cluster
  • D. vSAN Direct

Answer: A

Explanation:
Reference:
vSAN 6.7 expands the functionality of the vSAN iSCSI Target service to provide the SCSI-3 persistent reservations support for shared disks for windows failover cluster if using the SQL Server FCI, high availability mode is a requirement. The vSAN iSCSI Target service at the vSAN cluster level should be enabled for this purpose. VSAN streched cluster may be used to increase the data availability across data centres. https://blogs.vmware.com/virtualblocks/2019/03/26/considerations-for-running-microsoft-sql-server-workloads-on-vmware-vsan/


NEW QUESTION # 15
A company has engaged a consultant to upgrade an existing vSAN cluster to vSAN 7.0 U1. The company wants to ensure that the same vSAN process can be used in the future.
During the discovery phase, the consultant found the following information about the existing environment:
* The vCenter Server is currently version 7.0.
* The vSAN Cluster has the following configuration:
- vSAN version: 7.0
- Number of vSAN nodes: 6
- Encryption: enabled
- Deduplication and Compression: enabled
- Fault Domains: 1
- vSAN Capacity Utilization: 60%
* Each vSAN node has the following configuration:
- ESXi version: VMware vSphere 7.0
- CPU: 2 processors, 20 cores
- RAM: 1024GB RAM.
- Disk: 2 Cache SSDs and 6 Capacity SSDs
- Network: 4 x 10GbE
* All current hardware (which is from a single vendor) is listed on the vSAN Compatibility Guide for vSAN 7.
Which three recommendations should the consultant make to ensure that the vSAN cluster upgrade is completed? (Choose three.)

  • A. Upgrade all vSAN nodes to VMware vSphere 7.0 U1 using the baselines capability within VMware Update Manager (VUM).
  • B. Disable vSAN Encryption before starting the upgrade process.
  • C. Upgrade all vSAN nodes to VMware vSphere 7.0 U1 using the images capability within VMware Update Manager (VUM).
  • D. Choose the Allow reduced redundancy option.
  • E. Upgrade to VMware vCenter Server 7.0 U1.
  • F. Set VMware Distributed Resource Scheduling (DRS) to partially automated.

Answer: A


NEW QUESTION # 16
A company has engaged a consultant to upgrade an existing vSAN cluster to vSAN 7.0 U1. The company wants to ensure that the same vSAN process can be used in the future.
During the discovery phase, the consultant found the following information about the existing environment:
* The vCenter Server is currently version 7.0.
* The vSAN Cluster has the following configuration:
- vSAN version: 7.0
- Number of vSAN nodes: 6
- Encryption: enabled
- Deduplication and Compression: enabled
- Fault Domains: 1
- vSAN Capacity Utilization: 60%
* Each vSAN node has the following configuration:
- ESXi version: VMware vSphere 7.0
- CPU: 2 processors, 20 cores
- RAM: 1024GB RAM.
- Disk: 2 Cache SSDs and 6 Capacity SSDs
- Network: 4 x 10GbE
* All current hardware (which is from a single vendor) is listed on the vSAN Compatibility Guide for vSAN 7.
Which three recommendations should the consultant make to ensure that the vSAN cluster upgrade is completed? (Choose three.)

  • A. Upgrade all vSAN nodes to VMware vSphere 7.0 U1 using the images capability within VMware Update Manager (VUM).
  • B. Upgrade all vSAN nodes to VMware vSphere 7.0 U1 using the baselines capability within VMware Update Manager (VUM).
  • C. Disable vSAN Encryption before starting the upgrade process.
  • D. Choose the Allow reduced redundancy option.
  • E. Set VMware Distributed Resource Scheduling (DRS) to partially automated.
  • F. Upgrade to VMware vCenter Server 7.0 U1.

Answer: A,D,F


NEW QUESTION # 17
An organization has two vSAN clusters managed by the same vCenter Server, each providing 100TB of storage. The first cluster runs at 75% of its storage capacity, and the second cluster runs at 50% of its storage capacity.
The company also has the following:
* An iSCSI array of 300TB. which runs at 76% of its capacity
* A NAS system of 200TB, which runs at 10% of its capacity
* A Fiber channel (FC) array of 300TB, which runs at 80% of its capacity The administrator is asked to add an additional 25TB of storage to the first cluster. The administrator is also made aware that there is no budget to purchase new hardware and that the vSAN Storage Policy Based Management must be kept in place.
Which storage option will work for this use case?

  • A. Create an HCI Mesh using the first cluster's datastore.
  • B. Create an HCI Mesh using the second cluster's datastore.
  • C. Obtain additional free capacity from the existing NAS storage.
  • D. Obtain additional free capacity from the existing FC storage.

Answer: B

Explanation:
https://blogs.vmware.com/virtualblocks/2020/09/16/introducing-vmware-vsan-hci-mesh/


NEW QUESTION # 18
An administrator is setting up vSAN file services on a vSAN cluster.
Which two security policies on the distributed port groups are automatically enabled in the process? (Choose two.)

  • A. MacLearning
  • B. Jumbo Frames
  • C. Promiscuous Mode
  • D. DVFiltering
  • E. Forged Transmits

Answer: A,E

Explanation:
https://docs.vmware.com/en/VMware-vSphere/7.0/com.vmware.vsphere.vsan.doc/GUID-CA9CF043-9434-454E-86E7-DCA9AD9B0C09.html MacLearning and Forged Transmits are enabled as part of the vSAN File Services enablement process for a provided DVS port group.


NEW QUESTION # 19
During a design workshop for a stretched vSAN cluster, the requirement that some of the VMs be configured with no-mirror between sites was discussed.
Which three recommendations should the architect provide to address an event of a network partition between two sites? (Choose three.)

  • A. Host isolation response must exclude the VMs required
  • B. The default gateway must be used as the only isolation address
  • C. VMware vSphere DRS rules to force the VMs to run where the data resides
  • D. One of isolation addresses should reside in the site 2 data center
  • E. One of isolation addresses should reside in the site 1 data center
  • F. One isolation address reachable only from the witness appliance in both sites

Answer: A,C,D


NEW QUESTION # 20
In a stretched vSAN cluster, how is Read Locality established after fail over to the secondary site?

  • A. 50% of the reads comes from vSAN hosts on the local site
  • B. 50% of the reads comes from vSAN hosts on the remote site
  • C. 100% of the reads comes from vSAN hosts on the local site
  • D. 100% of the reads comes from vSAN hosts on the remote site

Answer: C


NEW QUESTION # 21
In a vSAN stretched cluster, which value must be set in the vSAN policy if there is no requirement for data mirroring across sites?

  • A. SFTT = 0
  • B. PFTT = 0
  • C. SFTT = 1
  • D. PFTT = 1

Answer: B

Explanation:
PFTT can be seen as "site failures", and you can always only tolerate 1 at most. SFTT can be seen as host failures, and you can define this between 0 and 3 https://www.yellow-bricks.com/2018/03/19/vsan-stretched-cluster-pftt-and-sftt-what-happens-when-a-full-site-fails-and-multiple-hosts-fail/


NEW QUESTION # 22
An administrator is tasked with migrating a VMware Horizon View environment that is currently running on an NFS Datastore to VMware vSAN.
Which Horizon configuration option will not be available when configuring vSAN in Horizon View?

  • A. Storage Profiles
  • B. Storage Tiers
  • C. Linked Clones
  • D. Instant Clones

Answer: B


NEW QUESTION # 23
An administrator is tasked with sharing storage from one vSAN cluster to another vSAN cluster. SPBM management must be preserved end-to-end, and the policy must be applied by the source vSAN cluster which is storing the dat a. Both vSAN clusters are managed by the same vCenter server.
What should the administrator configure?

  • A. vVOLs on vSAN
  • B. iSCSI targets on vSAN
  • C. NFS volumes on vSAN
  • D. HCI Mesh on vSAN

Answer: D


NEW QUESTION # 24
An administrator wants to check the performance metrics for the workloads and their virtual disks that are running on a vSAN cluster, but no statistical charts are displayed in the vSphere client.
Why is this behavior being seen?

  • A. vSAN proactive tests haven't been run yet.
  • B. vSAN network diagnostic mode is not enabled.
  • C. vSAN performance verbose mode is not enabled.
  • D. vSAN performance service is turned off.

Answer: D

Explanation:
Some tools allow for measuring latency peaks. This unfortunately isn't ideal, as it can unfairly represent statistical outliers, which may very well occur when there is little to no I/O activity. The best way to understand the actual behavior of VM and application latencies is to observe in time based performance graphs. Depending on the level of detail, you may need to measure at the individual VMDK level. Become familiar with these graphs to determine what is normal, and what is not for that given application. This is where you can use built-in functionality of vCenter and the vSAN performance service metrics to gather this information.
Reference:
https://docs.vmware.com/en/VMware-vSphere/7.0/com.vmware.vsphere.vsan-monitoring.doc/GUID-EF27701E-7BAC-4E76-9D2F-E1C58CAAB06D.html


NEW QUESTION # 25
An administrator wants to enable encryption on an existing vSAN cluster that already contains virtual machines.
Which additional step should the administrator take to ensure no data is lost during the encryption process?

  • A. Ensure that the vSAN Encryption is enabled by default on the existing cluster to encrypt old and new data.
  • B. Make vCenter Server trust the KMS, either by trusting the KMS or by uploading a KMS certificate.
  • C. Select 'Erase disks before use' check box when enabling encryption on a vSAN cluster.
  • D. Disable vSphere Distributed Resources Schedule (DRS) on the vSAN cluster.

Answer: C


NEW QUESTION # 26
An organization has two vSAN clusters managed by the same vCenter Server, each providing 100TB of storage. The first cluster runs at 75% of its storage capacity, and the second cluster runs at 50% of its storage capacity.
The company also has the following:
* An iSCSI array of 300TB. which runs at 76% of its capacity
* A NAS system of 200TB, which runs at 10% of its capacity
* A Fiber channel (FC) array of 300TB, which runs at 80% of its capacity The administrator is asked to add an additional 25TB of storage to the first cluster. The administrator is also made aware that there is no budget to purchase new hardware and that the vSAN Storage Policy Based Management must be kept in place.
Which storage option will work for this use case?

  • A. Obtain additional free capacity from the existing NAS storage.
  • B. Create an HCI Mesh using the second cluster's datastore.
  • C. Create an HCI Mesh using the first cluster's datastore.
  • D. Obtain additional free capacity from the existing FC storage.

Answer: A


NEW QUESTION # 27
An architect is working with an All-Flash vSAN configuration and will be using the Flash Caching Devices in vSAN.
Which requirement is specifically needed for these devices?

  • A. Capacity
  • B. Write endurance
  • C. Read endurance
  • D. IOPS

Answer: B


NEW QUESTION # 28
An administrator has received an alert indicating that a single capacity device is close to failing within the production vSAN Cluster. The administrator must now complete preemptive maintenance on the vSAN Cluster without impacting the availability of workloads or vSAN File Services.
The following information is known about the vSAN Cluster:
* vSAN 7.x Cluster
* vSAN node count: 8
* De-Duplication and Compression: Enabled.
* Encryption: Disabled
* Current Utilization: 45%
* Disk Groups: 2
* Devices per node: 2 x 400 GB SSD, 6 x 1.8 TB SSD
Which three steps should the administrator take to successfully complete the task? (Choose three.)

  • A. Put the affected vSAN host into maintenance mode to physically replace the storage device.
  • B. Remove the affected Disk Group from the vSAN Cluster, and choose Full Data Migration.
  • C. Remove the affected Disk from the Disk Group, and choose Full Data Migration.
  • D. Replace the failed disk with a storage device that is identical in class but smaller in capacity.
  • E. Replace the failed disk with a storage device that is identical in class and capacity.
  • F. Remove the affected Disk Group from the vSAN Cluster, and choose No Data Migration.

Answer: A,C,E

Explanation:
If you upgrade the capacity device, verify the following requirements:
- Verify that the cluster contains enough space to migrate the data from the capacity device.
- Place the host in maintenance mode. See Place a Member of Virtual SAN Cluster in Maintenance Mode.
"Select the flash capacity device or magnetic disk, and click Remove selected disk(s) from disk group."
https://docs.vmware.com/en/VMware-vSphere/6.5/com.vmware.vsphere.virtualsan.doc/GUID-4E3390C1-6C50-49E5-AEB6-C9BC037979A1.html


NEW QUESTION # 29
A company has deployed a 12-node (6-6-1) vSAN 7.0 stretched cluster for all production workloads.
The customer currently uses four different vSAN storage policies for running the workloads depending on the applications requirements:
* Policy 1 - Site Disaster Tolerance=Dual Site Mirroring, FTT=Erasure Coding
* Policy 2 - Site Disaster Tolerance=Dual Site Mirroring, FTT=Mirroring
* Policy 3 - Site Disaster Tolerance=None - Keep Data on Preferred, FTT=Mirroring
* Policy 4 - Site Disaster Tolerance=None - Keep Data on Non-Preferred, FTT=Mirroring During the setup of the vSAN stretched cluster, the following VM/Host Rules were created:
* Preferred Site - Preferred Site workloads should run on DC1 hosts.
* Secondary Site - Secondary Site workloads should run on DC2 hosts.
Which two activities should the administrator complete to ensure that there is no impact to production services during the maintenance window in the Preferred Site? (Choose two.)

  • A. Update vSphere DRS site affinity rules so that Preferred Site workloads should not run on hosts in DC1.
  • B. Change the Site Disaster Tolerance setting in Policy 3 to be "Dual Site Mirroring".
  • C. Update vSphere DRS site affinity rules so that Preferred Site workloads must run on hosts in DC2.
  • D. Change the FTT setting in Policy 3 to be "Erasure Coding".
  • E. Change the Site Disaster Tolerance setting in Policy 4 to be "None - Keep Data on Preferred".

Answer: C,E


NEW QUESTION # 30
An administrator is planning to deploy cloud-native workloads onto the vSAN Direct datastore.
Which storage policy structure rule is supported?

  • A. Storage performance-based rules
  • B. vVOL storage rules
  • C. Host-based rules
  • D. Tag-based placement rules

Answer: C


NEW QUESTION # 31
An administrator has been tasked with enabling encryption for existing virtual machines on a vSAN cluster.
Which three prerequisites must be satisfied before completing the task? (Choose three.)

  • A. Verify if a role with privilege "Cryptographic operations.Migrate" is assigned
  • B. Create an encryption storage policy
  • C. Enable that the virtual machines are powered on
  • D. Verify if a role with privilege "Cryptographic operations.Encrypt new" is assigned
  • E. Establish a trusted connection with the KMS
  • F. Enable Data-In-Transit encryption first

Answer: C,D,E


NEW QUESTION # 32
......


VMware HCI Master Specialist certification is designed for professionals who want to demonstrate their expertise in VMware's hyper-converged infrastructure (HCI) solutions. The 5V0-21.21 exam is one of the requirements for obtaining this certification. 5V0-21.21 exam focuses on testing the candidate's knowledge and skills in designing, deploying, and managing VMware's HCI solutions, including VMware vSphere, vSAN, and NSX. 5V0-21.21 exam is intended for professionals who have at least six months of experience working with VMware's HCI solutions and have a good understanding of virtualization and networking concepts.

 

Genuine 5V0-21.21 Exam Dumps Free Demo Valid QA's: https://prepaway.testinsides.top/5V0-21.21-dumps-review.html